How to Winterize a Sprinkler System Before the First Freeze

A suburban lawn and an outdoor sprinkler backflow preventer in late fall.

Key Takeaways

  • Shut off the irrigation water and controller, then remove water from the pipes, sprinkler heads, valves, and backflow device before freezing weather arrives.
  • Use the drain method designed for your system; compressed-air blowouts require the correct equipment and operating limits.
  • Do not blow out a zone a second time after it is dry: Colorado State University Extension warns that friction and heat from air moving through dry pipes can cause damage.
  • Leave the backflow preventer’s valves in the winter position recommended for its design; CSU Extension specifies approximately 45 degrees for the ball valves it describes.

To winterize a sprinkler system before the first freeze, shut off its water supply, turn off the controller, and drain or properly blow out the irrigation lines and components. The goal is to remove trapped water that could freeze and expand; simply switching off the timer does not empty the system.

Why can a sprinkler system be damaged by freezing?

Water left in irrigation pipes or components can freeze and expand, potentially cracking pipes and fittings or damaging valves, sprinkler bodies, pumps, and backflow devices. Colorado State University Extension describes these risks and recommends preparing the system before winter rather than relying on the controller being off.

A sprinkler system is not just the visible heads in the lawn. Water may remain in underground lines, valve assemblies, above-ground backflow equipment, and hoses connected to the system. Bowmar Water and Sanitation District and Valley Sanitation District both advise shutting off the irrigation supply and draining water from system components.

  • Common misconception: Turning off the controller is not the same as draining the pipes. The controller stops scheduled watering, but water may still be sitting in the system.
  • Practical implication: Treat water shutoff, controller shutdown, and drainage as separate tasks. Completing only one or two can leave other parts unprepared.

When should you winterize before the first freeze?

Finish winterization before freezing conditions arrive in your area, with enough time to drain the system or arrange a qualified blowout. The City of Englewood, Colorado, advises preparing sprinklers before the first hard freeze and gives overnight temperatures below 28°F for several hours as its local trigger.

That 28°F guidance is from Englewood, not a universal date or temperature rule for every location. The first hard freeze varies by climate and year, so use local weather conditions and your water district or city’s seasonal guidance to set your timing.

  1. Check your local timing guidance. Look for instructions from your city or water district, especially if it provides a freeze threshold.
  2. Identify how your system drains. Find the irrigation shutoff, drain points, valve boxes, and backflow preventer before cold weather is imminent.
  3. Leave time for the full job. If your system needs compressed air and you do not have the required equipment or instructions, schedule qualified help rather than guessing at settings.

What should you do before draining the sprinkler system?

Start by locating the main irrigation shutoff and the controller, then identify the drainage method and the system’s backflow preventer. Colorado State University Extension’s procedure begins by slowly closing the main shutoff valve upstream of the backflow device.

Before opening drains or disconnecting components, use this checklist. Knowing where each part is located helps you avoid treating the controller as the water shutoff or overlooking water trapped around the backflow assembly.

  • Find the valve that shuts off water to the irrigation system.
  • Locate the timer or automatic controller so you can turn it off for the season.
  • Find the drain valves or other drain points, including those at valve boxes if your system has them.
  • Locate the backflow preventer and note whether its instructions describe test cocks, isolation ball valves, or optional drain plugs.
  • Determine whether your system is designed for manual draining, compressed-air blowout, or another method specified by its manufacturer or installer.

Do not dismantle a backflow device just because another system’s winterization instructions show that step. CSU Extension’s instructions describe a particular device arrangement, including check valves and test cocks; components and procedures can differ. If you cannot identify the device or its correct drain procedure, use its product instructions or arrange qualified service.

How do you drain a sprinkler system manually?

If your system has manual drain valves, use the drain points provided for that system and allow water to leave each part. LawnStarter’s winterization guidance describes opening low-point drain valves one at a time, while the local district guidance also emphasizes draining pipes, sprinklers, and hoses.

Manual draining is appropriate only when your system has usable drain points and its instructions support that method. A drain valve may remove water from one section without emptying every line, valve, or backflow component, so follow the layout rather than assuming one open drain clears the entire installation.

  1. Shut off the irrigation water. Close the system’s supply valve. CSU Extension specifies closing the main shutoff slowly for the backflow assembly procedure it describes.
  2. Turn off the controller. Bowmar Water and Sanitation District recommends turning off the timer or automatic controller to prevent it from running.
  3. Open the intended drain points. If the system has low-point drains, open them one at a time and let each section drain before moving on.
  4. Drain accessible system components. Follow the system’s instructions for its valve boxes, sprinkler lines, hoses, and backflow device; do not assume that water has cleared from a part you have not drained.
  5. Set components for winter. Use the backflow device’s instructions for valve and test-cock positions. For the ball valves in its described procedure, CSU Extension says to leave them approximately 45 degrees while draining and in that position for winter.

Manual or automatic drain valves should not be treated as a universal substitute for a blowout. The correct approach depends on the system’s design. If the instructions call for compressed air, or you cannot tell whether manual drains clear all sections, do not improvise by increasing pressure or repeatedly opening and closing parts.

When is a compressed-air blowout the right choice?

A blowout uses compressed air to push water out of irrigation zones. Colorado State University Extension describes blowing out the irrigation system, and its guidance cautions that air moving through dry pipes creates friction and heat that could cause damage.

Use a blowout only when it is appropriate for your system and you can follow the equipment and system instructions. The material here does not provide a universal pressure, airflow, or compressor setting, so do not select one by guesswork. If you do not know the required limits, the safer practical choice is to have a qualified irrigation professional perform the blowout.

  1. Shut off the water supply and turn off the controller. These steps prepare the system for winter but do not themselves remove water.
  2. Use the designated compressor connection. CSU Extension notes that connecting the airline to a metal fitting rather than PVC can help dissipate some heat during blowout.
  3. Clear the zones using the system’s prescribed sequence and limits. Follow the manufacturer’s or service provider’s instructions; do not invent a pressure setting or hold a zone open beyond the specified procedure.
  4. Stop once a zone is blown out. CSU Extension specifically warns against blowing out a zone again after it is dry because friction and heat in dry pipes can cause damage.
  5. Prepare the backflow preventer separately. Clearing irrigation zones does not automatically mean the backflow device is drained or positioned for winter.

Do not assume that more air or another pass will make the job safer. The point is to remove water while staying within the system’s limits; running air through already-dry pipe can introduce heat without helping remove water.

How should you protect the backflow preventer?

A backflow preventer can hold water even when the irrigation zones have been drained, so it needs its own winter procedure. CSU Extension describes draining both sides of a particular device and leaving its isolation ball valves approximately 45 degrees during winter.

For that device, CSU Extension’s sequence includes opening test cocks #2 and #3 for the first check zone, draining water upstream through a stop-and-waste or other drain, then removing the downstream check cap, spring, and disk holder so water can drain through the body. It then says to replace the disk, spring, and check cap. These are device-specific steps, not instructions to disassemble every backflow preventer.

  • Before opening anything: Confirm that your backflow preventer matches the device and parts described in its instructions.
  • During draining: Use the correct drain points for the upstream and downstream sections. CSU Extension also says to remove optional drain plugs and test cocks #2 and #3 when the device is equipped with those features.
  • For winter storage: CSU Extension says to leave the described isolation ball valves about 45 degrees. It also says that if the PVB test cocks are left open, close them before turning the system on in spring.

If the device’s labels, parts, or instructions do not match that procedure, do not copy the steps mechanically. Use the instructions for your specific device or arrange qualified service; the wrong disassembly sequence can leave a component incorrectly reassembled.

What are the common winterization mistakes?

The most common errors are stopping after the controller is off, assuming a single drain clears every component, and repeating a blowout after a zone is dry. District guidance calls for shutting off water and draining the system, while CSU Extension specifically warns about heat damage from compressed air moving through dry pipes.

Problem or symptomLikely causeCheck and response
The controller is off, but water remains in the system.The timer was stopped without shutting off the irrigation supply and draining the lines.Locate the irrigation shutoff and drain points, then follow the system’s winterization method.
A drain is open, but some components have not been addressed.The drain may clear only one section; the backflow device, valve assembly, or another line may retain water.Compare the system layout with its instructions and identify each part that requires separate drainage.
A zone has already been cleared, but the blowout is repeated.The operator assumes another pass will improve the result.Stop. CSU Extension warns that air moving through dry pipes creates friction and heat that could cause damage.
The backflow valves are left fully open or fully closed without checking the device procedure.A position intended for one valve or device is applied to another.Follow the backflow device’s instructions. CSU Extension specifies approximately 45 degrees for the isolation ball valves in its procedure.
The system is turned on in spring while PVB test cocks are still open.The winter position was not reset before startup.If PVB test cocks were left open, CSU Extension says to close them before turning the system on in spring.

Use the table as a troubleshooting guide, not as a substitute for the device instructions. If you find a mismatch between the system parts and the steps you planned to follow, pause and identify the correct procedure before applying air or removing components.

Should you winterize the system yourself or hire help?

Manual winterization is a reasonable option when the system has clearly identified drain points and you know how to drain each section. A professional blowout is a practical choice when the system requires compressed air and you do not know the correct equipment limits or backflow procedure.

Your situationPractical next stepWhy
You can identify manual drains and have instructions for all system sections.Shut off the supply and controller, then drain each section and the backflow device as directed.Manual drains can be used when they are provided for the system and the instructions explain what they clear.
Your system’s instructions call for compressed air, and you know the specified limits.Follow the specified blowout method and stop after each zone is cleared.CSU Extension warns that repeated air through dry pipes can create damaging friction and heat.
You cannot identify the backflow device or its winter position.Use the device instructions or arrange qualified service before disassembly.CSU Extension’s detailed valve and check-component steps apply to the described device arrangement.
You are a renter and do not know who controls the irrigation shutoff.Check the property’s maintenance instructions and identify who is responsible for the irrigation system before operating valves.This avoids changing settings on shared equipment without knowing how the system is arranged.

For homeowners, keep a simple record of where the shutoff, controller, drains, and backflow preventer are located. For renters, take note of whether the irrigation equipment serves only your unit or shared outdoor areas, and use the property’s maintenance process when the shutoff or drain procedure is unclear.

What should you check before spring startup?

Before turning the irrigation system on in spring, return winterized parts to their operating positions and check that the backflow device has been reassembled as directed. CSU Extension specifically says to close PVB test cocks before spring startup if they were left open during winter.

  1. Confirm that drain plugs, check caps, springs, and other removed parts have been returned to their specified positions.
  2. Close PVB test cocks that were left open for winter, as directed by CSU Extension.
  3. Check that valves are no longer in the winter drainage position before restoring normal operation.
  4. Restore the water supply and controller according to your system’s instructions, then watch for leaks or parts that do not operate normally.

If you see a leak or a damaged component when restarting, shut off the irrigation supply and identify the affected part before running the system further. Avoid forcing a valve or repeatedly cycling a zone when the system is not operating as expected.

Frequently Asked Questions

Is turning off the sprinkler timer enough for winter?

No. Turning off the controller prevents scheduled watering, but it does not remove water from irrigation lines or the backflow device. Shut off the irrigation supply and drain the system using the method intended for its design.

Can I use manual drain valves instead of a blowout?

That depends on the system’s design and instructions. Manual drains may not clear every section or component, so do not assume they are sufficient just because water stops coming out of one drain.

What air pressure should I use for a sprinkler blowout?

There is no universal setting given here. Use the system and equipment manufacturer’s specified limits; if you cannot identify them, arrange qualified service rather than guessing.

Should I blow out a zone again if it looks dry?

No. Colorado State University Extension warns that compressed air moving through dry pipes creates friction and heat that could cause damage. Stop once the zone has been blown out.

When should I close the PVB test cocks in spring?

If the PVB test cocks were left open for winter, close them before turning the system on in spring, as CSU Extension instructs. Follow the instructions for your specific backflow device if its configuration differs.

Key points to remember

Winterizing means more than switching off a timer: shut off the irrigation supply, turn off the controller, and remove water from the system’s lines and components before freezing weather. Choose manual draining or a blowout based on the system’s instructions, not guesswork.

  • Use local freeze guidance to plan timing; Englewood’s below-28°F-for-several-hours threshold is a local example, not a nationwide rule.
  • Drain the backflow preventer according to its own procedure.
  • Do not repeat a blowout on a dry zone, and do not invent compressor settings.
  • Before spring startup, return winterized parts to their proper positions and close PVB test cocks that were left open.

Freeze timing and device procedures differ by location and system. Check current local guidance and the instructions for your sprinkler and backflow equipment before acting.

References

Information in this post was checked as of October 2026. Policies and prices may change, so please verify important details with official sources.